Quality Network, Inc.

 

Ultrasonic Testing

EMAT Testing

Eddy Current Testing

Scanning Equipment

Case Depth Testing

Material Analysis

NDT Software

Home

 About Us

Download Links Contact Us Search Support

  

PCUS®pro Multi

 

 

 

System Features

The PCUS®pro multi-channel ultrasonic frontend is designed to meet requirements of  high data acquisition rates and high inspection speeds. In combination with custom software modules, the user can inspect parts and components effectively at high quality levels.

System Characteristics 

General

  • USB 2.0 High-Speed with a maximum of 40MB/sec data transfer rate

  • Dimensions: 190mm x 150mm x 65mm (L, W, H)

  • Near-transducer setup

   Transmitter

  • Maximum of 16 independent transmitters

  • Transmitter pulse voltage: -10 to -300V, adjustable in 1V increments, or switchable between -175V and -260V (optional) 

  • Negative rectangle pulse

  • Output impedance: 50Ω

  • Pulse delay: 0µs to 51µs, adjustable in 6.25ns increments

  • Pulse width: 0ns to 500ns, adjustable in 3.125ns increments

  • Pulse repetition frequency: up to 2kHz, depending on recording length, pulse width, sampling rate and transmitter voltage

   Receiver

  • Maximum of 16 independent receivers

  • Pulse/Echo or Transmit/Receive mode (1 x P/E or 1 x T/R per channel)

  • Frequency range: 500kHz to 30MHz (-3dB)

  • Receiver filter: two analog band filters per channel (user defined)

  • Attenuation/amplification: >100dB, adjustable in 0.1dB increments

  • TGC with 80dB dynamic range, adjustable in 0.1dB increments; 256 points,
    slope ≤ 40dB/µs

  • Receiver delay: 0µs to 819µs, adjustable in 12.5ns increments

  • Input sensitivity: 100μVss

   Signal Path

  • Transducer delay: 0μs to 819μs, 12.5ns increments

  • Maximum recording length: 65,535 samples per channel

  • A/D Converter: 14bit, max. 80MS/sec

  • One start gate and four measurement gates

  • RF-Data or compressed TD-Data recording

  • Rectification:  positive-, negative- or full-wave

  • Trigger delay per channel: 0µs to 819µs, adjustable in 12.5ns increments

   Interface and Connectors

  • Transducer connectors: Lemo 00

  • USB 2.0 High-Speed: Bulgin Connector PX0443

  • Power consumption: max. 12VDC, max. 48W (30W typical); Bulgin Connector PX0419

  • Trigger IN: TTL high/low active; pulse width >100ns, opto-coupled (Lemo 00)

  • Trigger OUT: LVTTK high active, pulse width >2.5µs (Lemo 00)

  • Scanner interface: DSCU-25 socket (4 encoders, RS422.485)

   Software

  • Digitally signed drivers for Windows® XP (SP2 or higher), Windows® Vista and Windows® 7 (32bit and 64bit)

  • Managed Windows® API (based on .NET 4.0 framework)

The PCUS®pro Multi system meets all relevant requirements of DIN EN 12668, Part 1.


Information Request Form PCUSpro Multi, Technical Data

 
 

Copyright © 1996-2015 Quality Network, Inc. All rights reserved
Last modified: October 02, 2016